The H61 series oil‑immersed distribution transformer is independently developed and manufactured by Hengfengshuai Electric. It is widely deployed in overhead distribution networks, rural grid renovation and commercial & industrial outdoor power distribution scenarios. High‑voltage side adopts top incoming connection, while the low‑voltage side is equipped with triangular surge arresters. It is suitable for pole‑mounted and open‑air platform installation and supports customized delivery for power grid projects in multiple regions.
We support custom kVA capacity, voltage combinations, protection accessories and anti‑corrosion treatment to adapt to various regional grid standards and ambient conditions, compatible with both 50Hz and 60Hz power systems for global projects.
Every unit undergoes a complete set of factory tests prior to shipment to satisfy requirements from overseas power operators, EPC contractors and industrial end users.

H61 Distribution Transformer Features
Energy Efficiency Compliant for European Utility Distribution Networks Designed in accordance with European harmonized standards EN 50464‑1, EN 50588‑1 together with IEC 60076 series international standards. Loss performance meets EU Ecodesign Regulation EU No.548/2014. CE certification is available complying with LVD Directive 2014/35/EU and EMC Directive 2014/30/EU, and DoC declaration can be supplied. It satisfies EDF grid access specifications and can operate reliably in France, Germany, Spain, Italy, Belgium, Poland and other EU member states. It also serves markets in North Africa and the Middle East that adopt European standards. Under rated operating conditions with regular maintenance, the design service life reaches 25 years, and the practical service life can extend to 30–35 years with favorable operating maintenance.Typical Application Scenarios For H61 Distribution Transformer
Solar PV & Distributed Renewable Energy Stations
H61 series pole-mounted distribution transformer serves as a step-down unit for small ground-mounted solar farms, mini hydro and distributed wind projects. It converts medium voltage to low voltage for inverter output and supports grid interconnection with stable voltage regulation.
Commercial Complexes & Residential Estates
H61 series pole-mounted distribution transformer supplies overhead power for suburban residential blocks, neighbourhood shops, retail outlets and community service facilities. It adopts pole mounting design without occupying ground space, perfectly matching overhead distribution networks.
Light Industry & Agricultural Irrigation
H61 series pole-mounted distribution transformer delivers steady power for small processing workshops, grain mills, water pump sets and farm irrigation systems. It can withstand fluctuating motor loads and adapt to outdoor open-air environments.
Municipal & Public Utility Facilities
H61 series pole-mounted distribution transformer is widely deployed for street lighting, water supply pumping stations, rural telecom base stations and roadside public facilities. The oil-immersed structure features strong environmental adaptability for long-term outdoor operation.
Rural Grid Reinforcement & Remote Electrification
H61 series pole-mounted distribution transformer is the core unit for overhead rural distribution feeders, rural electrification and grid expansion projects. It is easy to install on concrete or utility poles and suitable for sparsely populated remote areas.
Temporary Power Supply for Field Projects
H61 series pole-mounted distribution transformer provides reliable power for field exploration, road construction and remote site works. It can be quickly hoisted and commissioned, and reused after project completion.
| Market | Base Standard | Core Mandatory Certification |
|---|---|---|
| EU, Middle East, Nepal, Ethiopia, Rwanda, Ecuador | IEC 60076 series | CE + IEC Type Test Report + COC for customs clearance |
| South Africa | SANS 60076, SANS 780 | NRCS / SABS |
| Chile | IEC 60076 series | SEC |
| Brazil | NBR 5356 | INMETRO |
| Zambia | IEC 60076 series | ZABS (ZC) |
| Kenya, Tanzania, Nigeria | IEC 60076 series | PVoC / TBS / SONCAP + COC |
| Factory Tests and Reports | ||
| Routine Tests (free of charge) | Type Tests (chargeable) | Special Tests (chargeable) |
| 1) Winding resistance test | 1) Temperature rise test | 1) Special insulation test |
| 2) Voltage ratio measurement and connection group symbol verification | 2) Insulation type test | 2) Measurement of winding hot-spot temperature rise |
| 3) Measurement of short-circuit impedance and load loss | 3) Sound level determination for each cooling method | 3) Measurement of capacitance to earth and between windings |
| 4) Measurement of no-load loss and no-load current | 4) Power measurement of fan and oil pump motors | 4) Measurement of dielectric dissipation factor of the insulation system capacitance |
| 5) Measurement of DC resistance to earth and between windings | 5) Measurement of no-load loss and no-load current at 90%–100% of rated voltage | 5) Determination of transient voltage transfer characteristics |
| 6) Routine insulation test | 6) Measurement of zero-sequence impedance of three-phase transformers | |
| 7) On-load tap changer test | 7) Short-circuit withstand test | |
| 8) Pressure sealing test for liquid-immersed transformers | ||
| 9) Pressure sealing test for gas-filled transformer tanks | ||
| 10) Ratio and polarity test of built-in current transformers | ||
| 11) Insulation measurement of core and clamps of liquid-immersed transformers | ||
| 12) Insulating liquid test | ||
| Transformer Test Items and Relevant Standards | ||
| 1. Winding resistance measurement (GB 1094.1, Clause 10.2) | ||
| 2. Voltage ratio measurement and connection group symbol verification (GB 1094.1, Clause 10.3) | ||
| 3. Measurement of short-circuit impedance and load loss (GB 1094.1, Clause 10.4) | ||
| 4. Measurement of no-load current and no-load loss (GB 1094.1, Clause 10.5) | ||
| 5. Measurement of winding-to-earth insulation resistance and/or dielectric dissipation factor of the insulation system capacitance (GB/T 6451) | ||
| 6. Routine insulation test (GB 1094.3) | ||
| 7. On-load tap changer test (GB 1094.1, Clause 10.8) | ||
| 8. Insulating oil test (GB 1094.1, Clause 10.9) | ||
| 9. Special tests | ||
| 9.1 Special insulation test (GB 1094.3) | ||
| 9.2 Measurement of zero-sequence impedance of three-phase transformers (GB 1094.1, Clause 10.7) | ||
| 9.3 Sound level determination (GB 7328) | ||
Different countries and electrical utilities have different requirements for distribution transformers. Hengfengshuai supports customized configurations based on individual project conditions.
Available customization options include:
* Rated capacity and voltage ratio.
* Single-phase or three-phase configuration.
* Copper or aluminum winding.
* 50Hz or 60Hz operating frequency.
* Off-circuit tap changer configuration.
* Lightning protection and accessory selection.
* Outdoor corrosion protection.
* Customized nameplates and technical documentation.
Please provide your required voltage, capacity, frequency, and installation conditions when requesting a quotation.
Get Customized Solution
Why Choose HENGFENGSHUAI H61 Distribution Transformer?
H61 series oil‑immersed distribution transformer is engineered to comply with IEC 60076 and European EN standards, meeting EU Ecodesign Regulation EU No.548/2014. CE‑certified and compatible with EDF grid‑access requirements for France, suitable for EU member states, North‑African and Middle‑East markets adopting European norms. Design service life reaches 25 years (30‑35 years with proper maintenance). IP53 fully‑sealed weather‑proof construction works reliably within‑25℃ ~ +45℃ ambient temperature, fit for pole‑mounted and open‑air platform installation.
Customizable kVA rating, voltage ratio, vector group, copper / aluminium windings, 50Hz / 60Hz frequency, anti‑corrosion grade, French‑English bilingual nameplates. Tailor‑made configurations for overhead distribution, rural electrification, oil‑gas & mining facilities, commercial‑industrial projects and renewable‑energy grid‑connection. OEM & ODM project‑based supply available.
Manufactured under ISO 9001 quality‑management system. Every H61 unit completes full FAT (Factory Acceptance Test) before shipment. Third‑party witnessed test by SGS / BV is available; English test reports support grid acceptance and customs clearance. Traceable supply‑chain control covers raw‑material incoming inspection through final finished‑product check.
Products exported to over 50 countries worldwide. Fast lead‑time: as short as 15 days for standard distribution‑transformer orders. Complete export‑grade packaging, full‑set English drawings, O&M manuals and export documentation are provided. We coordinate global logistics and offer one‑stop sourcing to simplify procurement for overseas buyers.
Pre‑sales support includes product‑selection and technical proposal review. Witness‑factory inspection is welcome. After‑sales services cover remote commissioning guidance and trouble‑shooting. 12‑hour initial technical response upon fault notification; on‑site service can be arranged per project contract. We serve EPC contractors, power distributors and industrial end‑users globally.
Q1: Which standards does the H61 oil immersed distribution transformer comply with?
A1: It follows IEC 60076 series, EN 50464‑1, EN 50588‑1. The loss level meets EU Ecodesign Regulation EU No.548/2014. It is CE certified under LVD 2014/35/EU and EMC 2014/30/EU. For France EDF projects, we can supply extra EDF grid‑specific technical documents.
Q2: Can this transformer be used for France and other EU countries?
A2: Yes. It is designed for 50Hz EU grid, compatible with France 20kV distribution network, also suitable for Germany, Spain, Italy, Belgium, Poland and other EU member states. It can also be supplied for markets adopting European standards.
Q3: What is the design service life of this transformer?
A3: The design service life is 25 years under rated load and regular maintenance. With good operating environment and proper maintenance, the actual service life can reach 30–35 years.
Q4: What is the working ambient temperature range?
A4: Standard design ambient temperature: -25℃ ~ +40℃, short‑term peak ambient temperature up to +45℃.
Q5: Will you provide FAT report for customs clearance and grid acceptance?
A5: Every unit will complete full FAT (Factory Acceptance Test) before shipment. English FAT report is provided. Witnessed test by SGS / BV is available on request for EU customs and power grid inspection.
Q6: Can you customize the transformer parameters and nameplate?
A6: Yes. We can adjust voltage ratio, vector group and anti‑corrosion grade. French‑English bilingual nameplate is optional. Complete English drawings, O&M manuals and test documents are available.
Q7: What protection devices are equipped as standard?
A7: Standard configuration: triangular surge arresters, pressure relief valve, oil level indicator and temperature measuring assembly. It meets EU local grid safety requirements.
Q8: What is the IP protection grade of the tank?
A8: The enclosure protection grade is IP53. Fully sealed tank structure is adopted for outdoor rainproof and dustproof operation.
Call To Action
Get H61 Distribution Transformer Price and Technical Datasheet
Contact HENGFENGSHUAI ELECTRIC for:
✔ Competitive transformer prices
✔ IEC standard manufacturing
✔ Customized solutions
✔ Global delivery support
|
Item |
Specification |
|---|---|
|
Rated Capacity |
50kVA, 100kVA, 160kVA (extended customization available) |
|
Rated Frequency |
50Hz (EU standard), 60Hz optional |
|
HV Voltage |
3.3kV‑36kV, customizable for common 20kV France grid |
|
LV Voltage |
400‑430V (standard European low voltage); other voltages on request |
|
HV Insulator |
3 pcs HV porcelain bushings |
|
LV Insulator |
4 pcs LV porcelain bushings |
|
Protection Devices |
Triangular surge arrester, pressure relief valve, oil level gauge, temperature sensor set |
|
Lifting Structure |
4 lifting lugs for integral hoisting |
|
Bottom Structure |
4 welded rollers for easy on‑site transportation |
|
Earthing |
2 dedicated earthing terminals complying with EU earthing safety codes |
|
Nameplate & Docs |
French‑English bilingual nameplate optional, with quality warranty document |
|
Vector Group |
Dyn11 as standard, customizable |
|
Cooling Type |
ONAN |
|
Enclosure IP Grade |
IP53 |
|
Design Ambient Temp |
‑25℃ ~ +40℃, short‑term peak +45℃ |
|
Design Service Life |
25 years under rated condition with periodic maintenance |
|
Target Markets |
France, Germany, Spain, Italy, Belgium, Poland and other EU countries, also regions adopting European standards |
|
Applicable Standards |
IEC 60076‑1/2/3/4/5, EN 50464‑1, EN 50588‑1, EU ErP No.548/2014 |
|
Certifications |
CE (LVD 2014/35/EU, EMC 2014/30/EU); special EDF grid access documentation package optional |
H61 Distribution Transformer Ordering Instructions
Looking for a reliable H61 oil immersed distribution transformer manufacturer?
Contact Hengfengshuai Electric for customized H61 transformer solutions for overhead distribution networks, rural electrification, industrial facilities, and infrastructure projects.
Send us your technical specifications and project requirements to receive a product proposal and quotation.
Get H61 Transformer Price & Datasheet Now










Qingdao Hengfengshuai Electric Co., Ltd
WhatsApp: +86 152 6625 8801
Address: No. 251, Xingyang Road, Chengyang District, Qingdao, Shandong
Email: hfs@hengfengshuai.com
Customer service email: service@hengfengshuai.com
website:https://www.hengfengshuai.com