产品中心
Your current location :Home > Product > Distribution Transformer >

H61 Distribution Transformer | Oil Immersed Pole Mounted Transformer

  • Classification: Distribution Transformer
  • Number of Views: 143次
  • Date of issue: 2026-11-12 13:08:47


  • Product overview:

    H61 Oil Immersed Distribution Transformer

     

    The H61 series oil‑immersed distribution transformer is independently developed and manufactured by Hengfengshuai Electric. It is widely deployed in overhead distribution networks, rural grid renovation and commercial & industrial outdoor power distribution scenarios. High‑voltage side adopts top incoming connection, while the low‑voltage side is equipped with triangular surge arresters. It is suitable for pole‑mounted and open‑air platform installation and supports customized delivery for power grid projects in multiple regions.
     

    We support custom kVA capacity, voltage combinations, protection accessories and anti‑corrosion treatment to adapt to various regional grid standards and ambient conditions, compatible with both 50Hz and 60Hz power systems for global projects.
     

    Every unit undergoes a complete set of factory tests prior to shipment to satisfy requirements from overseas power operators, EPC contractors and industrial end users.


Product advantages
 
H61 Distribution Transformer
 

H61 Distribution Transformer Features

Energy Efficiency Compliant for European Utility Distribution Networks Designed in accordance with European harmonized standards EN 50464‑1, EN 50588‑1 together with IEC 60076 series international standards. Loss performance meets EU Ecodesign Regulation EU No.548/2014. CE certification is available complying with LVD Directive 2014/35/EU and EMC Directive 2014/30/EU, and DoC declaration can be supplied. It satisfies EDF grid access specifications and can operate reliably in France, Germany, Spain, Italy, Belgium, Poland and other EU member states. It also serves markets in North Africa and the Middle East that adopt European standards. Under rated operating conditions with regular maintenance, the design service life reaches 25 years, and the practical service life can extend to 30–35 years with favorable operating maintenance.

Outdoor Weather‑Resistant Sealed Structure Adopting fully sealed tank construction with enclosure protection grade IP53. The design ambient temperature range is ‑25℃ ~ +40℃, with short‑time peak tolerance up to +45℃. Rainproof and dustproof features are well suited for open‑air overhead installation in rural and suburban areas across Europe. Welded rollers are fitted at the tank bottom for easy on‑site movement and positioning.

Complete Protection Components Standard configuration includes triangular surge arresters, pressure relief valve, oil level indicator and temperature measuring assembly. Multi‑layer protection is provided against overvoltage, overtemperature and internal faults to reduce long‑term outdoor operation risks and meet local EU power grid safety & maintenance requirements.

Standard Factory Inspection with Export Documentation Support Every unit undergoes a complete set of FAT (Factory Acceptance Test) before shipment. Routine tests and sampling type tests are fully covered. Witnessed tests by third‑party agencies such as SGS or BV are available. English FAT reports can be issued to satisfy EU customs clearance and grid acceptance review.

Flexible Customization Besides standard parameters, voltage ratio, vector group and anti‑corrosion grade can be adjusted to fit regional grid differences among EU countries. Nameplates can be produced in bilingual French & English. Complete English drawings, test reports and operation & maintenance manuals are supplied to match delivery specifications for customers in France and the EU.

Typical Application Scenarios For H61 Distribution Transformer
 

Solar PV & Distributed Renewable Energy Stations
H61 series pole-mounted distribution transformer serves as a step-down unit for small ground-mounted solar farms, mini hydro and distributed wind projects. It converts medium voltage to low voltage for inverter output and supports grid interconnection with stable voltage regulation.

Commercial Complexes & Residential Estates
H61 series pole-mounted distribution transformer supplies overhead power for suburban residential blocks, neighbourhood shops, retail outlets and community service facilities. It adopts pole mounting design without occupying ground space, perfectly matching overhead distribution networks.

Light Industry & Agricultural Irrigation
H61 series pole-mounted distribution transformer delivers steady power for small processing workshops, grain mills, water pump sets and farm irrigation systems. It can withstand fluctuating motor loads and adapt to outdoor open-air environments.

Municipal & Public Utility Facilities
H61 series pole-mounted distribution transformer is widely deployed for street lighting, water supply pumping stations, rural telecom base stations and roadside public facilities. The oil-immersed structure features strong environmental adaptability for long-term outdoor operation.

Rural Grid Reinforcement & Remote Electrification
H61 series pole-mounted distribution transformer is the core unit for overhead rural distribution feeders, rural electrification and grid expansion projects. It is easy to install on concrete or utility poles and suitable for sparsely populated remote areas.

Temporary Power Supply for Field Projects
H61 series pole-mounted distribution transformer provides reliable power for field exploration, road construction and remote site works. It can be quickly hoisted and commissioned, and reused after project completion.


H61 Distribution Transformer Standards & Certifications

 
Market Base Standard Core Mandatory Certification
EU, Middle East, Nepal, Ethiopia, Rwanda, Ecuador IEC 60076 series CE + IEC Type Test Report + COC for customs clearance
South Africa SANS 60076, SANS 780 NRCS / SABS
Chile IEC 60076 series SEC
Brazil NBR 5356 INMETRO
Zambia IEC 60076 series ZABS (ZC)
Kenya, Tanzania, Nigeria IEC 60076 series PVoC / TBS / SONCAP + COC

 

H61 Distribution Transformer FAT (Factory Acceptance Test) Items

 

 

Factory Tests and Reports
Routine Tests (free of charge) Type Tests (chargeable) Special Tests (chargeable)
1) Winding resistance test 1) Temperature rise test 1) Special insulation test
2) Voltage ratio measurement and connection group symbol verification 2) Insulation type test 2) Measurement of winding hot-spot temperature rise
3) Measurement of short-circuit impedance and load loss 3) Sound level determination for each cooling method 3) Measurement of capacitance to earth and between windings
4) Measurement of no-load loss and no-load current 4) Power measurement of fan and oil pump motors 4) Measurement of dielectric dissipation factor of the insulation system capacitance
5) Measurement of DC resistance to earth and between windings 5) Measurement of no-load loss and no-load current at 90%–100% of rated voltage 5) Determination of transient voltage transfer characteristics
6) Routine insulation test   6) Measurement of zero-sequence impedance of three-phase transformers
7) On-load tap changer test   7) Short-circuit withstand test
8) Pressure sealing test for liquid-immersed transformers    
9) Pressure sealing test for gas-filled transformer tanks    
10) Ratio and polarity test of built-in current transformers    
11) Insulation measurement of core and clamps of liquid-immersed transformers    
12) Insulating liquid test    
Transformer Test Items and Relevant Standards
1.   Winding resistance measurement (GB 1094.1, Clause 10.2)
2.   Voltage ratio measurement and connection group symbol verification (GB 1094.1, Clause 10.3)
3.   Measurement of short-circuit impedance and load loss (GB 1094.1, Clause 10.4)
4.   Measurement of no-load current and no-load loss (GB 1094.1, Clause 10.5)
5.   Measurement of winding-to-earth insulation resistance and/or dielectric dissipation factor of the insulation system capacitance (GB/T 6451)
6.   Routine insulation test (GB 1094.3)
7.   On-load tap changer test (GB 1094.1, Clause 10.8)
8.   Insulating oil test (GB 1094.1, Clause 10.9)
9.   Special tests
9.1  Special insulation test (GB 1094.3)
9.2  Measurement of zero-sequence impedance of three-phase transformers (GB 1094.1, Clause 10.7)
9.3  Sound level determination (GB 7328)



Customized H61 Transformer Solutions

 

Different countries and electrical utilities have different requirements for distribution transformers. Hengfengshuai supports customized configurations based on individual project conditions.
 

Available customization options include:

        *  Rated capacity and voltage ratio.

        *  Single-phase or three-phase configuration.

        *  Copper or aluminum winding.

        *  50Hz or 60Hz operating frequency.

        *  Off-circuit tap changer configuration.

        *  Lightning protection and accessory selection.

        *  Outdoor corrosion protection.

        *  Customized nameplates and technical documentation.
 

Please provide your required voltage, capacity, frequency, and installation conditions when requesting a quotation.

   Get Customized Solution     



Why Choose HENGFENGSHUAI H61 Distribution Transformer?
 

✅ Professional Product Performance for EU‑standard Markets

H61 series oil‑immersed distribution transformer is engineered to comply with IEC 60076 and European EN standards, meeting EU Ecodesign Regulation EU No.548/2014. CE‑certified and compatible with EDF grid‑access requirements for France, suitable for EU member states, North‑African and Middle‑East markets adopting European norms. Design service life reaches 25 years (30‑35 years with proper maintenance). IP53 fully‑sealed weather‑proof construction works reliably within‑25℃ ~ +45℃ ambient temperature, fit for pole‑mounted and open‑air platform installation.


✅ Flexible Customization for Project‑specific Requirements

Customizable kVA rating, voltage ratio, vector group, copper / aluminium windings, 50Hz / 60Hz frequency, anti‑corrosion grade, French‑English bilingual nameplates. Tailor‑made configurations for overhead distribution, rural electrification, oil‑gas & mining facilities, commercial‑industrial projects and renewable‑energy grid‑connection. OEM & ODM project‑based supply available.


✅ Strict Full‑range Quality & Export‑oriented Testing

Manufactured under ISO 9001 quality‑management system. Every H61 unit completes full FAT (Factory Acceptance Test) before shipment. Third‑party witnessed test by SGS / BV is available; English test reports support grid acceptance and customs clearance. Traceable supply‑chain control covers raw‑material incoming inspection through final finished‑product check.


✅ Rich Overseas‑project Execution & On‑time Delivery

Products exported to over 50 countries worldwide. Fast lead‑time: as short as 15 days for standard distribution‑transformer orders. Complete export‑grade packaging, full‑set English drawings, O&M manuals and export documentation are provided. We coordinate global logistics and offer one‑stop sourcing to simplify procurement for overseas buyers.


✅ Full‑lifecycle Technical Support

Pre‑sales support includes product‑selection and technical proposal review. Witness‑factory inspection is welcome. After‑sales services cover remote commissioning guidance and trouble‑shooting. 12‑hour initial technical response upon fault notification; on‑site service can be arranged per project contract. We serve EPC contractors, power distributors and industrial end‑users globally.



H61 Distribution Transformer FAQ

 

Q1: Which standards does the H61 oil immersed distribution transformer comply with?
A1: It follows IEC 60076 series, EN 50464‑1, EN 50588‑1. The loss level meets EU Ecodesign Regulation EU No.548/2014. It is CE certified under LVD 2014/35/EU and EMC 2014/30/EU. For France EDF projects, we can supply extra EDF grid‑specific technical documents.

 

Q2: Can this transformer be used for France and other EU countries?
A2: Yes. It is designed for 50Hz EU grid, compatible with France 20kV distribution network, also suitable for Germany, Spain, Italy, Belgium, Poland and other EU member states. It can also be supplied for markets adopting European standards.

 

Q3: What is the design service life of this transformer?
A3: The design service life is 25 years under rated load and regular maintenance. With good operating environment and proper maintenance, the actual service life can reach 30–35 years.

 

Q4: What is the working ambient temperature range?
A4: Standard design ambient temperature: -25℃ ~ +40℃, short‑term peak ambient temperature up to +45℃.

 

Q5: Will you provide FAT report for customs clearance and grid acceptance?
A5: Every unit will complete full FAT (Factory Acceptance Test) before shipment. English FAT report is provided. Witnessed test by SGS / BV is available on request for EU customs and power grid inspection.

 

Q6: Can you customize the transformer parameters and nameplate?
A6: Yes. We can adjust voltage ratio, vector group and anti‑corrosion grade. French‑English bilingual nameplate is optional. Complete English drawings, O&M manuals and test documents are available.

 

Q7: What protection devices are equipped as standard?
A7: Standard configuration: triangular surge arresters, pressure relief valve, oil level indicator and temperature measuring assembly. It meets EU local grid safety requirements.

 

Q8: What is the IP protection grade of the tank?
A8: The enclosure protection grade is IP53. Fully sealed tank structure is adopted for outdoor rainproof and dustproof operation.


 

Call To Action

Get H61 Distribution Transformer Price and Technical Datasheet

Contact HENGFENGSHUAI ELECTRIC for:

✔ Competitive transformer prices
✔ IEC standard manufacturing
✔ Customized solutions
✔ Global delivery support

Request Quote Now



Product parameters

H61 Distribution Transformer Selection Table

Item

Specification

Rated Capacity

50kVA, 100kVA, 160kVA (extended customization available)

Rated Frequency

50Hz (EU standard), 60Hz optional

HV Voltage

3.3kV‑36kV, customizable for common 20kV France grid

LV Voltage

400‑430V (standard European low voltage); other voltages on request

HV Insulator

3 pcs HV porcelain bushings

LV Insulator

4 pcs LV porcelain bushings

Protection Devices

Triangular surge arrester, pressure relief valve, oil level gauge, temperature sensor set

Lifting Structure

4 lifting lugs for integral hoisting

Bottom Structure

4 welded rollers for easy on‑site transportation

Earthing

2 dedicated earthing terminals complying with EU earthing safety codes

Nameplate & Docs

French‑English bilingual nameplate optional, with quality warranty document

Vector Group

Dyn11 as standard, customizable

Cooling Type

ONAN

Enclosure IP Grade

IP53

Design Ambient Temp

‑25℃ ~ +40℃, short‑term peak +45℃

Design Service Life

25 years under rated condition with periodic maintenance

Target Markets

France, Germany, Spain, Italy, Belgium, Poland and other EU countries, also regions adopting European standards

Applicable Standards

IEC 60076‑1/2/3/4/5, EN 50464‑1, EN 50588‑1, EU ErP No.548/2014

Certifications

CE (LVD 2014/35/EU, EMC 2014/30/EU); special EDF grid access documentation package optional

 


     Get Technical Proposal     

Ordering instructions

H61 Distribution Transformer Ordering Instructions
 

Looking for a reliable H61 oil immersed distribution transformer manufacturer?
 

Contact Hengfengshuai Electric for customized H61 transformer solutions for overhead distribution networks, rural electrification, industrial facilities, and infrastructure projects.
 

Send us your technical specifications and project requirements to receive a product proposal and quotation.
 

Get H61 Transformer Price & Datasheet Now  


label:

Online Message

Comments or suggestions can be submitted to us

Qingdao Hengfengshuai Electric Co., Ltd      

WhatsApp: +86 152 6625 8801     

Address: No. 251, Xingyang Road, Chengyang District, Qingdao, Shandong

Email: hfs@hengfengshuai.com      

Customer service email: service@hengfengshuai.com      

website:https://www.hengfengshuai.com

whatsapp
(+86) 152 6625 8801
WhatsApp Click Contact